WaveInjector®
The WaveInjector® is a special transducer mounting fixture
which makes it possible to use standard ultrasonic flow
transducers at extreme temperatures.
|
Temperature range
Diameter range:
Material:
Hazardous area classification:
|
-160 °C to 400 °C
40 mm to1000 mm
Stainless steel
Since the WaveInjector® is a purely mechanical device,
it can be used without any further certification in explosion hazard areas.
|
|
|
The transducers
All FLEXIM transducers are calibrated as a pair at the works.
The calibration can be traced back to national and international
standards. The calibration data and the transducer parameters
are permanently stored in the transducers themselves.
An extended calibration can be carried out on demand.
|
Operating temperature,
standard transducers:
Operating temperature,
high temperature transducers:
Operating temperature
with WaveInjector®:
Degree of protection
acc. to EN 60529:
Material:
Hazardous area classification:
|
-40 °C to 130 °C
-30 °C to 200 °C
up to 400 °C
IIP65, IP67 or IP68 depending on type (EN60529); NEMA 4X
Stainless steel or PEEK with stainless steel protective cap
FM Class I Div II and ATEX zone 1 & 2 types available
|
|
The matched FLUXUS® flowmeters:
|
|
|
FLUXUS® F601. The portable meter.
|
Operating temperature:
Flow channels:
Degree of protection:
|
-10 °C to 60 °C
2
Umformer: IP65 gem. EN60529
Koffer: IP67 gem. EN60529
|
|
|
FLUXUS® ADM 7407/7907. The multi-function meters.
|
Operating temperature:
Flow channels:
Degree of protection acc. to EN60529:
Hazardous area classification:
|
-10 °C to 60 °C
1 oder 2
F7407: IP65, F7907: IP20
F7407: ATEX Zone 2
or FM Class I Div II optional
|
|
|
FLUXUS® ADM 8027/8127.
The explosion-proof experts.
|
Operating temperature:
Flow channels:
Degree of protection:
Hazardous area classification:
|
ADM 8027: -20 °C to 60 °C;
ADM 8127: -20 °C to 50 °C
1 or 2
IP66 acc. to EN60529
ATEX zones 1 und 2
|
|
|
|
|
|